Spectrum-controls 1746sc-INI4vi Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Urządzenia pomiarowe Spectrum-controls 1746sc-INI4vi. Spectrum Controls 1746sc-INI4vi User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
Owners Guide 0300127-04 Rev. F
SLC 500
I
SOLATED
A
NALOG
I
NPUT
M
ODULES
Catalog Numbers
1746sc-INI4i
1746sc-INI4vi
Przeglądanie stron 0
1 2 3 4 5 6 ... 57 58

Podsumowanie treści

Strona 1 - 1746sc-INI4vi

Owner’s Guide 0300127-04 Rev. FSLC 500™ ISOLATEDANALOG INPUT MODULESCatalog Numbers1746sc-INI4i1746sc-INI4vi

Strona 2

6 SLC 500™ Isolated Analog Input ModulesFull-scale range (FSR) – The difference between the maximum andminimum specified analog values.Gain drift – Th

Strona 3 - Important Notes

Overview And SpecificationsThe 1746sc-INI4i monitors up to 4 isolated analog current inputs, whilethe 1746sc-INI4vi monitors up to 4 isolated analog c

Strona 4

8 SLC 500™ Isolated Analog Input ModulesState-of-the-Art PerformanceThese modules incorporate proprietary Allen-Bradley technology, so theyoperate and

Strona 5 - Table Of Contents

Chapter 1: Overview And Specifications 9Table 3. Electrical specifications—inputsInput Current Ranges 4 to 20 mA(selectable for each channel) 0 to 20

Strona 6 - Appendix A

10 SLC 500™ Isolated Analog Input ModulesTable 4. Physical specificationsLED Indicators Four green channel status indicators, one for each channelOne

Strona 7 - Documents

Installing And Wiring Your ModuleRead this chapter to install and wire your module. This chapter covers:• avoiding electrostatic damage• determining p

Strona 8 - You Should Know

12 SLC 500™ Isolated Analog Input ModulesAvoiding ElectrostaticDamageGuard against electrostatic damage by observing the followingprecautions:CAUTIONE

Strona 9 - Preface 5

Chapter 2: Installing And Wiring Your Module 13Selecting A Rack SlotTwo factors determine where you should install your module in the rack:ambient tem

Strona 10 - 6 SLC 500

14 SLC 500™ Isolated Analog Input Modules2. Slide your module into the chassis until both top and bottom retainingclips are secure. Apply firm even pr

Strona 11 - Chapter

Chapter 2: Installing And Wiring Your Module 152. At each end of the cable, strip some casing to expose the individualwires.3. Trim the exposed signal

Strona 13 - ±352 µV/°C

16 SLC 500™ Isolated Analog Input Modules7. Repeat steps 1 through 6 for each channel on your module.A system may malfunction due to a change in its o

Strona 14

Chapter 2: Installing And Wiring Your Module 17Table 7. Input module terminal block connections.Pin Label Function Channel0 V IN 0 + High differential

Strona 15

18 SLC 500™ Isolated Analog Input ModulesFigure 2. Wiring schematic for 2-, 3-, and 4-wire analog inputsImportant: Your module does not provide power

Strona 16 - Avoiding Electrostatic

Things To Consider Before UsingYour ModuleRead this chapter to familiarize yourself with:• how the processor communicates with your module• the differ

Strona 17 - Into The Rack

20 SLC 500™ Isolated Analog Input ModulesFigure 4. Image table for your isolated analog input moduleOutput ImageSlot eInput ImageSlot eSLC 5/0XData Fi

Strona 18 - Wiring Your Module

Chapter 3: Things To Consider Before Using Your Module 21Important – A data word is valid only when the channel is enabled andthere are no channel err

Strona 19

22 SLC 500™ Isolated Analog Input ModulesIn general, you can reduce the channel update time by doing any of thefollowing:• disabling unused channels•

Strona 20 - 16 SLC 500

Chapter 3: Things To Consider Before Using Your Module 23Table 9. Channel update time(based on number of channels enabled and filter frequency)Filter

Strona 21

24 SLC 500™ Isolated Analog Input ModulesFigure 7. Signal attenuation with 60 Hz input filter0-20-40-60-80-100-120-140-160-180-2000 60 120 180 240 300

Strona 22

Chapter 3: Things To Consider Before Using Your Module 25Figure 9. Signal attenuation with 500 Hz input filter0-20-40-60-80-100-120-140-160-180-2000 5

Strona 23

Important Notes1. Read all the information in this guide before installing the product.2. The information in this owner's guide applies to hardwa

Strona 24 - 20 SLC 500

26 SLC 500™ Isolated Analog Input ModulesYour Module’sResponse To SlotDisablingBy writing to the status file in the modular SLC processor, you candisa

Strona 25 - Step Response Time

Using Your Input ModuleRead this chapter to:• enter your input module’s ID code• configure each input channel• set the user-defined scale limits (opti

Strona 26 - Frequency

28 SLC 500™ Isolated Analog Input ModulesConfiguring Each InputChannelAfter installing your module, you must configure each channel by settingbit valu

Strona 27

Chapter 4: Using Your Input Module 29Table 13. Input channel configuration word (O:e.0 through O:e.3)Use these bit settings in the channel configurati

Strona 28 - 24 SLC 500

30 SLC 500™ Isolated Analog Input ModulesInput Channel Enable (configuration bit 0)Use this bit to enable or disable a channel. To minimize update tim

Strona 29 - Disable Times

Chapter 4: Using Your Input Module 31Table 14. Data format definitionsSelected Actual Signal Limits Count LimitsData Format Input Range Min. Max. Min.

Strona 30 - Disabling

32 SLC 500™ Isolated Analog Input ModulesOpen Input Circuit Response (configuration bits 7 and 8)For 1–5 Vdc and 4–20 mA inputs only, use this bit fie

Strona 31

Chapter 4: Using Your Input Module 33Setting The User-Defined Scale Limits(optional)For special applications (such as when using a sensor with a non-s

Strona 32 - Configuring Each Input

34 SLC 500™ Isolated Analog Input ModulesThe following equations show you how to convert user-defined scaleunits (or any type of units) to engineering

Strona 33

Chapter 4: Using Your Input Module 35In the preceding example...Slow= 3.5 Ulow= 100Shigh= 20.5 Uhigh= 9999∆S= 17 ∆U= 9899Monitoring Each InputChannelT

Strona 35

36 SLC 500™ Isolated Analog Input ModulesTable 15. Input channel status word (I:e.4 through I:e.7)These bit settings in the status word151413121110987

Strona 36 - 32 SLC 500

Chapter 4: Using Your Input Module 37The first 12 status bits reflect the settings in the channel configurationword. The remaining status bits flag th

Strona 37 - (optional)

38 SLC 500™ Isolated Analog Input Modules

Strona 38 - 34 SLC 500

Programming ExamplesRead this chapter to familiarize yourself with how to use the advancedfeatures of your module for:• PID control• user-defined scal

Strona 39 - And Status

40 SLC 500™ Isolated Analog Input ModulesFigure 12. Programming for PID control example.Rung 2:1 Channel 0 StatusI:3.4 ] [ 0PIDPIDControl Block

Strona 40

Chapter 5: Ladder Program Examples 41User-Defined ScalingYour input module was designed to work directly with applicationsrequiring special data scali

Strona 41

42 SLC 500™ Isolated Analog Input Modules

Strona 42 - 38 SLC 500

Testing Your ModuleRead this chapter to prevent potential problems in a systematic andcontrolled way. This chapter covers:• inspecting your module• di

Strona 43

44 SLC 500™ Isolated Analog Input Modules2. Ensure that the shield for the cable used to wire your module isproperly grounded. Refer to Chapter 2, Ins

Strona 44 - User Manual

Chapter 6: Testing Your Module 45Interpreting The LEDIndicatorsYour module has five LEDs: four channel status LEDs (numbered 0–3for channels 0–3, resp

Strona 45 - User-Defined Scaling

PrefaceWho Should Use This Guide... 3What This Guide Covers ...

Strona 46 - 42 SLC 500

46 SLC 500™ Isolated Analog Input ModulesTroubleshootingFigure 18. Problem resolution flowchartModuleStatus LED(s)off.Module faultcondition.Check to s

Strona 47

Maintaining Your ModuleAnd Ensuring SafetyRead this chapter to familiarize yourself with:• preventive maintenance• safety considerationsThe National F

Strona 48 - Powering Up

48 SLC 500™ Isolated Analog Input ModulesStanding Clear Of Machinery – When troubleshooting a problem withany SLC 500 system, have all personnel remai

Strona 49 - Interpreting I/O Error

Verifying CalibrationRead this chapter to verify your module’s calibration.To verify your module’s calibration, you need:• a precision input source wh

Strona 50 - Troubleshooting

50 SLC 500™ Isolated Analog Input Modules2. Let the operating temperature stabilize for 2 minutes.3. Use the precision input source to provide a 15 m

Strona 51

Index1746-NI4 compatibility, 30, 31AAbbreviations 4Accuracy 6, 9Addressing 19–21Ambient temperature 13Analog-to-digital conversion 4, 8APS 27Att

Strona 52

52 SLC 500™ Isolated Analog Input ModulesInspection 43Installation 13–14Isolation 7, 8JJumper 11LLadder programming 19examples 39LEDs 7, 10, 45

Strona 53 - Appendix

Getting TechnicalAssistanceIf you need technical assistance, please review the information in Chapter6, “Testing Your Module,” before calling your loc

Strona 54 - (-INI4vi only)

The ENCOMPASS logo and SLC 500 are trademarks of Allen-Bradley Company, Inc. Copyright © 1998-2004, Spectrum Controls, Inc. All rightsreserved. Printe

Strona 55

ii SLC 500™ Isolated Analog Input ModulesMaintaining Your ModuleAnd Ensuring SafetyChapter 7Preventive Maintenance...

Strona 56

PrefaceRead this preface to familiarize yourself with the rest of the owner’sguide. This preface covers:• who should use this guide• what this guide p

Strona 57 - Conformity

4 SLC 500™ Isolated Analog Input ModulesTable 1. Related Allen-Bradley documentationAllen-Bradley Doc. No. Title1747-2.30 SLC 500 System OverviewSGI-1

Strona 58

Preface 5channel to convert the data received from the processor to analog outputsignals at the terminals.Chassis – See rack.Common mode rejection – T

Komentarze do niniejszej Instrukcji