Counter / Flow Meter Input Module
49
Example : Demultiplexing Data
The following ladder logic shows how to move data from the 4 multiplexed input words to a block of 8 output words starting
at location 400001 using the manual mode. This and other ladder logic samples may be found on our website,
www.spectrumcontrols.com.
Rung 1 demultiplex data or channels 1 and 2 - Rung 2 demultiplexes data or channels 3 and 4
Rung 3 demultiplex data or channels 5 and 6 - Rung 4 demultiplexes data or channels 7 and 8